Clean air. More space. Efficient processes.

The central extraction solution for your dental lab—powerful, energy-efficient, and custom-designed.

The FZ VARIO is the central extraction solution for dental labs with multiple workstations. It ensures reliable dust extraction, frees up space in the lab, and supports efficient workflows—all tailored to your specific needs.

Central Vacuum System

More than just extraction. A better work environment.

A central exhaust system offers numerous benefits for your day-to-day lab work. It captures dust and other contaminants directly at the connected workstations and equipment. The exhaust unit itself is installed outside the work area.

More space for your lab.

  • Clean Workstations: Dust and grinding residue are extracted directly at the workstations.

  • More space: The centralized system reduces the number of individual extraction units in the lab.

  • Quieter operation: The extraction system is installed outside the actual workstations.

  • Efficient operation: The suction power adjusts to actual needs.

  • Less maintenance: Automatic filter cleaning ensures reliable operation.

Would you like to equip your lab with a central exhaust system or expand an existing system? We’ll support you every step of the way—from the initial idea through planning to installation.

Extraction exactly when you need it.

The automatic suction port openers are standard equipment in the Zubler central suction system. They ensure that suction air is directed to the workstation only when dust is actually being generated.

For example, as soon as you activate your handpiece or a connected device such as a sandblaster or a CAD/CAM system, the corresponding extraction port opens automatically. After you turn it off, the extraction system runs for a short time to capture any remaining dust.

For you, this means: on-demand extraction, less unnecessary energy consumption, and targeted dust collection directly at the source.

Your lab is unique. So is your fume hood system.

A central fume extraction system must be tailored to your lab’s spatial conditions, workstations, and workflows. That’s why a good fume extraction solution doesn’t start with the equipment—it starts with planning.

Our experts analyze your equipment, the number of extraction points required, and the structural conditions. Based on this, we develop a tailored solution—from piping design to professional installation.

Ready for the future: The FZ VARIO system can be flexibly expanded. Additional fume hood controls and piping can be retrofitted if the lab is expanded later. The integration of additional fume hoods should be taken into account during the initial overall planning.

Frequently Asked Questions About Central Vacuum Systems

The FZ VARIO is suitable for dental labs with multiple workstations and varying extraction requirements. The system is designed to fit the size of your lab and the connected equipment.

That depends on the specific configuration, the connected devices, and the required ventilation capacity. We’ll design the system to fit your lab.

The filters are automatically cleaned with compressed air at set intervals. This helps maintain consistent suction performance and reduces the need for manual cleaning.

The system can be adapted to changing requirements within the limits of what is technically feasible. That is why we also take potential future expansions into account during the planning phase.

Since the vacuum cleaner is set up outside the actual work area—for example, in an adjacent room or in the basement—there is no direct noise from the vacuum motor at the workplace. An integrated exhaust silencer further reduces the system’s noise level.

 
Feature FZ10 FZ20
Dimensions (L x W x H) 720 x 1917 x 600 mm 2,100 x 2,030 x 600 mm
Weight 200 kg 230 kg
Rated Power Consumption 600–2,500 W 600–2,500 W
Total volume 20–300 L 20–300 L
Simultaneous suction points 12 14
Dust Container Capacity 40 L 40 l
Dust Class M M
Effective filter area 10 m² 20 m²
Filter System Compressed Air Backwash Compressed-air backwash
Sound Pressure Level 52–71 dB(A) 52–71 dB(A)
Suction connections 2 x 100 mm 2 x 100 mm
Exhaust air connection 100 mm 100 mm
Compressed air connection at least 5 bar at least 5 bar

The right extraction system starts with good planning.

Every dental lab has different requirements. We’ll help you find the right central vacuum system—tailored to your workstations, equipment, and spatial conditions.